Actions
crash #113
openShort-cut on High Voltage during Charging @ 500W
crash #113:
Short-cut on High Voltage during Charging @ 500W
Start date:
03/18/2026
Description
After there is less current, the temperature starts to rise. At 289, the short-cut happens and the MOSFET HV crashes. Look at the attached file for more information. We need to investigate this further, as the problem seems to be linked to a decrease in power consumption. The software version is 6b07dafc52147ea3a0b860710c4b836f7228f79f.
Files
Updated by Tristan Scropetta 25 days ago
- Description updated (diff)
Updated by Tristan Scropetta 25 days ago
- Description updated (diff)
Updated by Mitis Admin 22 days ago
- File Thrust_opt.xlsx added
Updated by Mitis Admin 22 days ago
- File deleted (
Thrust_opt.xlsx)
Updated by Tristan Scropetta 12 days ago
- File query.iqy added
Updated by Tristan Scropetta 12 days ago
- File deleted (
query.iqy)
Updated by Tristan Scropetta 12 days ago
Actions